Bitte verwenden Sie diesen Link, um diese Publikation zu zitieren, oder auf sie als Internetquelle zu verweisen: https://hdl.handle.net/10419/187874 
Erscheinungsjahr: 
2016
Quellenangabe: 
[Journal:] Energy Reports [ISSN:] 2352-4847 [Volume:] 2 [Publisher:] Elsevier [Place:] Amsterdam [Year:] 2016 [Pages:] 261-266
Verlag: 
Elsevier, Amsterdam
Zusammenfassung: 
The paper present an evaluation of a grid-connected photovoltaic (PV) system installed on the roof of a government building located in Tangier, Morocco. The experimental data was recorded from 1st January 2015 to December 2015 based on real time observation. The aim is to encourage the use of solar PV system for government, commercial and residence building in Morocco based on the obtained results. The system is made up of 20 modules of 250 Wp and one inverter of 5 kW. The assessed parameters of the PV installation includes energy output, final yield, modules temperature, efficiency module, performance ratio (PR) and others. The PV park supplied the grid with 6411.3 kWh during the year 2015. The final yield (Yf) ranged from 1.96 to 6.42 kWh/kWp, the performance ratio (PR) ranged from 58% to 98% and the annual capacity factor was found to be 14.84%. The final yield of PV installation is compared with other final yields of solar PV systems located at other places. Finally various power losses are given through a diagram loss.
Schlagwörter: 
Performance ratio
Diagram losses
Final yield
Photovoltaic installations
State building
Persistent Identifier der Erstveröffentlichung: 
Creative-Commons-Lizenz: 
cc-by-nc-nd Logo
Dokumentart: 
Article
Erscheint in der Sammlung:

Datei(en):
Datei
Größe





Publikationen in EconStor sind urheberrechtlich geschützt.